E-mail sinonshseo@gmail.com
Time:2025-03-28 14:00:16 Reading volume:911
The regeneration oil filter should be used and managed by the equipment specialist. At the same time, the inspection and test responsibility system for handheld and mobile electric appliances must be strictly implemented, and qualified equipment must be used.
1. The power supply wiring should strictly follow the temporary power supply layout and connection management system at the construction site.
2. When connecting fixed or mobile pipes, ensure that the pipe interface is firmly connected and there is no leakage.
3. The oil filter interface of the oil tank should be an interface. The oil filter should not be directly inserted into the oil tank. If this method is required, the oil filter pipeline must be clean and fixed to avoid the oil pipe from being immersed too deeply in the liquid surface.
4. When starting, the inlet and outlet doors of the oil filter should be opened at the same time to prevent damage to the oil seal or collapse of the oil filter pipeline.
5. Oil filters with different uses and media must not be mixed. In special circumstances, the oil filter must be cleaned before use.
6. Check the filter element regularly according to the degree of oil cleanliness, and replace the filter element in time if necessary.
7. Someone must be on site during the oil filtering process, and the machine must be shut down immediately if any abnormality is found.
8. When the oil filter machine is intermittent or out of service, its power supply must be disconnected and the relevant throttle must be closed.
9. Clean up the site after the oil filtering, wipe the equipment, and remove the temporary oil pipe.
Notes:
1. Before starting the heating device, you must be able to see that there is oil in the level gauge on the oil-water separator
2. Before starting the oil pump, at least one of the oil outlet valves must be open
3. Before shutting down, you must turn off the heating device
4. The oil cannot enter the plate and frame filter before the water in the oil is cleaned
5. When discharging the water in the sewage collection system, you should shut down the raw material roasting plant first
First turn off the heating system, turn off the oil inlet valve after 5-10 minutes, then turn off the vacuum pump, open the vacuum return valve, let the vacuum degree of the oil-water separator drop to normal pressure, continue to run the oil pump, and turn off the oil pump when there is basically no oil flowing out of the oil outlet pipe, close all valves, and cut off the main power supply.